Product Details:
Payment & Shipping Terms:
|
Body: | Aluminum | Core And Plugnut: | Stainless Steel |
---|---|---|---|
Core Spring: | Stainless Steel | Working Pressure: | 0.35-0.85Mpa |
Sealing & Disc: | CR (chloroprene) | Diaphragm: | NBR(nitrile/buna-n) Or Viton |
Diaphragm Seat: | PA-6 (standard) | Port Size: | 1 1/2" |
High Light: | Diaphragm Pulse Valve,Dust Collector Pulse Valves |
Goyen Die cast Aluminum diaphragm valve CA45T 010-300 1 1/2 " AC230V pulse jet valve
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
INSTAllATION:
1 | Fully pressurise system. |
2 | Test fire and listen for proper actuation and crisp pulse noise. |
3 | Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). |
4 | Spare parts kit and replacement coils are available |
5 | Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. |
6 | Ensure tank and pipes are free from dirt, rust or other particulate. |
7 | Ensure supply air is clean and dry. |
8 | Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. |
9 | Apply moderate pressure to system and check for installation leaks. |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K4502 / K4503(Vition)